SETIF=NONE, SAMPLECLK=LFACLK, SAMPLE=ACMPCOUNT, EXMODE=DISABLE, EXCLK=LFACLK
No Description
THRES | ACMP threshold or DAC data |
EXMODE | Set GPIO mode 0 (DISABLE): Disabled 1 (HIGH): Push Pull, GPIO is driven high 2 (LOW): Push Pull, GPIO is driven low 3 (DACOUT): DAC output |
ALTEX | Use alternative excite pin |
SAMPLECLK | Select clock used for timing of sample d 0 (LFACLK): LFACLK will be used for timing 1 (AUXHFRCO): AUXHFRCO will be used for timing |
EXCLK | Select clock used for excitation timing 0 (LFACLK): LFACLK will be used for timing 1 (AUXHFRCO): AUXHFRCO will be used for timing |
SETIF | Enable interrupt generation 0 (NONE): No interrupt is generated 1 (LEVEL): Set interrupt flag if the sensor triggers. 2 (POSEDGE): Set interrupt flag on positive edge of the sensor state 3 (NEGEDGE): Set interrupt flag on negative edge of the sensor state 4 (BOTHEDGES): Set interrupt flag on both edges of the sensor state |
OFFSET | OFFSET for IADC/ACMP interaction |
SAMPLE | Sample mode Selection 0 (ACMPCOUNT): undefined 1 (ACMP): undefined 2 (ADC): undefined 3 (ADCDIFF): undefined |